Product Categories
- Webster Hardness Tester (22)
- Rockwell Hardness Tester (4)
- Brinell Hardness Tester (0)
- Crush Tester (1)
- Leeb Hardness Tester (20)
- Coating Thickness Guage (90)
- Ultrasonic Flaw Detector (34)
- Ultrasonic Thickness Gauge (109)
High accuracy (1%+1)
Split design, strong applicability, measured value stability
Short response time, fast measurement speed.
7 kinds of sensors (F400, F1, F1/90 °, F10, N400, N1, CN02) are available to meet customer needs, a variety of measurement
Temperature:0℃~50℃ Humidity:20%~90%
enquirycoating thickness gauge prices
coating thickness gauge prices is designed for measuring the thickness of coating. The feature for this meter is fast , non-destructive and accurate.
Cpad Coating Thickness Gauge is applied in many areas, such as electroplating industry, corrosion protection, aerospace industry, automotive car industry, ship building industry , light industry and inspection, etc.
Cpad could meet your diffrent demands by changing diffrent probes. There are two measuring methods could be chosen, magnetic permeability method and eddy current method.
F type probe with magnetic method, can measure the magnetic metal (such as steel, iron, alloy steel and hard magnetic and non-magnetic) thickness of coating layer (such as zinc,aluminum, chromium, copper, rubber, paint etc.)
N probe can be measured by the eddy current method, the non ferromagnetic metal (such as copper, aluminum, zinc, tin and other) non conductive cover layer thickness and austenitic stainless steel (such as: plastic, rubber, paint, anodizing etc.).
Probe Mode | F400 | F1 | F1/90 | F10 | N400 | N1 | CN02 | ||||
Working Principle | Magenetic Permeability Method | Eddy Current Method | |||||||||
Mesuring range | 0~400 | 0~1250 | 0~10000 | 0~400 | 0~1250 | 10~200 | |||||
( Copper covered with chomium 0~40) | |||||||||||
Resolution (mm) | 0.1 | 0.1 | 10 | 0.1 | 0.1 | 1 | |||||
Tolera (mm) | One point calibration(mm) | ±(3%H+0.7) | ±(3%H+1) | ±(3%H+10) | ±(3%H+0.7) | ±(3%H+1.5) | ±(3%H+1) | ||||
Tne point calibration(m) | ±(1%H+0.7) | ±((1%H+1) | ±(1%H+10) | ±(1%H+0.7) | ±(1%H+1.5) | ——– | |||||
Measuring Condition | The minimum radius of curvature(mm) | 凸 | 1 | 1.5 | Straight | 10 | 凸 | 1.5 | 3 | Straight | Straight Only |
The minimum area diameter(mm) | F3 | F7 | F7 | F4 | F4 | F5 | F5 | F7 | |||
The critical thickness of the matrix(mm) | 0.2 | 0.5 | 0.5 | 2 | 0.3 | 0.3 | 0.3 | Unlimited |
Measuring Range of coating thickness gauge prices
F400:0~400μm N400:0~400μm
F1:0~1250μm F1/90:0~1250μm
N1:0~1250μm F10:0~10000μm
CN02:10~200μm
Accuracy
F400、N400 Probe
One point calibration: (2%+0.7)
Two point calibration:±(1%+0.7)
F1、F1/90、N1、CN02 Probe
One point calibration:±(2%+1)
Two point calibration:±(1%+1)
F10 Probe
One point calibration:±(2%+10)
Two point calibration:±(1%+10)
Calibration method
One point calibration / two point calibration / Basic Calibration
Resolution:0.1μm(0-99.9μm)
1μm (over100μm)
Probe Mode | F400 | F1 | F1/90 | F10 | N400 | N1 | CN02 | ||||
Working Principle | Magenetic Permeability Method | Eddy Current Method | |||||||||
Mesuring range | 0~400 | 0~1250 | 0~10000 | 0~400 | 0~1250 | 10~200 | |||||
( Copper covered with chomium 0~40) | |||||||||||
Resolution (mm) | 0.1 | 0.1 | 10 | 0.1 | 0.1 | 1 | |||||
Tolera (mm) | One point calibration(mm) | ±(3%H+0.7) | ±(3%H+1) | ±(3%H+10) | ±(3%H+0.7) | ±(3%H+1.5) | ±(3%H+1) | ||||
Tne point calibration(m) | ±(1%H+0.7) | ±((1%H+1) | ±(1%H+10) | ±(1%H+0.7) | ±(1%H+1.5) | -------- | |||||
Measuring Condition | The minimum radius of curvature(mm) | 凸 | 1 | 1.5 | Straight | 10 | 凸 | 1.5 | 3 | Straight | Straight Only |
The minimum area diameter(mm) | F3 | F7 | F7 | F4 | F4 | F5 | F5 | F7 | |||
The critical thickness of the matrix(mm) | 0.2 | 0.5 | 0.5 | 2 | 0.3 | 0.3 | 0.3 | Unlimited |
Base Coating
|
Organic materials and other non metallic coating (such as: paint, paint, enamel,etc)
Plastic and anodizing etc.)
|
||
Cover thickness < 100mm | Cover thickness > 100mm | ||
Such as magnetic metal iron, steel etc. | Measuring Area > 30mm | F400: 0~400mm
F1 : 0~1250mm |
F400 :0~400mm
F1 :0~1250mm F10 :0~10mm |
Measuring Area < 30mm | F400: 0~400mm | F1 : 0~1250mm
F400: 0~400mm |
|
Such as copper, aluminum, tin etc. | Measuring Area > 10mm | N400 :0~400mm
N1 :0~1250mm |
N400 0~400mm
N1 : 0~10mm |
Measuring Area < 10mm | N400 :0~400mm | N1 : 0~1250mm
N400: 0~400mm |
Testing Probe Reference(2)
Probe Coating
|
Non magnetic metal layer (such as: chromium, zinc, aluminum,copper, tin, silver, etc.) | ||
Cover thickness < 100mm | Cover thickness < 100mm | ||
Such as magnetic metal iron, steel etc. | Measuring Area > 30mm | F400: 0~400mm
F1: 0~1250mm |
F400: 0~400mm
F1: 0~1250mm F10: 0~10mm |
Measuring Area < 30mm | F400: 0~400mm | F400:0~400µm
F1: 0~1250mm |
|
Such as copper, aluminum, tin etc. | Measuring Area > 10mm | Only for copper plating N400: 0~40mm | -------- |
Measuring Area < 10mm | -------- | -------- | |
Plastic, non metal base | Measuring Area > 7mm | CN02: 10~200mm | CN02: 10~200mm |
Testing Probe Reference(3)
Mode | Cpad T200 | Cpad T210 | Cpad T220 |
Probe | F | N | N、F |