-FOB Portable Hardness Tester-
    [email protected]
EnglishAfrikaansБългарскиCatalàBinisayaChinyanjaHrvatskiČeštinaDanskNederlandsEsperantoSuomiFrançaisDeutschΕλληνικάहिन्दी; हिंदीÍslenskaBahasa IndonesiaItaliano한국어ພາສາລາວLatīnaBahasa MelayuमराठीМонголनेपालीNorskPortuguêsRomânăРусскийEspañolSvenskaతెలుగుTürkçeУкраїнськаTiếng Việtèdè YorùbáisiZuluбашҡорт телемарий йылмеGàidhligудмурт кыл

Coating Thickness Guage

» Coating Thickness Guage

  • coating thickness gauge supplier

    CATEGORY AND TAGS:
    Coating Thickness Guage

    High accuracy (1%+1)
    Split design, strong applicability, measured value stability
    Short response time, fast measurement speed.
    7 kinds of sensors (F400, F1, F1/90 °, F10, N400, N1, CN02) are available to meet customer needs, a variety of measurement

    Temperature:0℃~50℃ Humidity:20%~90%

    enquiry
    • Specifications
    • Principle
    • Test Probe Reference 1
    • Test Probe Reference 2

    coating thickness gauge supplier

    coat thickness gauge is designed for measuring the thickness of coating. The feature for this meter is fast , non-destructive and accurate.
    Cpad Coating Thickness Gauge is applied in many areas, such as electroplating industry, corrosion protection, aerospace industry, automotive car industry, ship building industry , light industry and inspection, etc.
    Cpad could meet your diffrent demands by changing diffrent probes. There are two measuring methods could be chosen, magnetic permeability method and eddy current method.
    F type probe with magnetic method, can measure the magnetic metal (such as steel, iron, alloy steel and hard magnetic and non-magnetic) thickness of coating layer (such as zinc,aluminum, chromium, copper, rubber, paint etc.)
    N probe can be measured by the eddy current method, the non ferromagnetic metal (such as copper, aluminum, zinc, tin and other) non conductive cover layer thickness and austenitic stainless steel (such as: plastic, rubber, paint, anodizing etc.).

    Probe Mode F400 F1 F1/90 F10 N400 N1 CN02
    Working Principle Magenetic Permeability Method Eddy Current Method
    Mesuring range 0~400 0~1250 0~10000 0~400 0~1250 10~200
    ( Copper covered with chomium  0~40)
    Resolution (mm) 0.1 0.1 10 0.1 0.1 1
    Tolera (mm) One point calibration(mm) ±(3%H+0.7) ±(3%H+1) ±(3%H+10) ±(3%H+0.7) ±(3%H+1.5) ±(3%H+1)
    Tne point calibration(m) ±(1%H+0.7) ±((1%H+1) ±(1%H+10) ±(1%H+0.7) ±(1%H+1.5) ——–
    Measuring Condition The minimum radius of curvature(mm) 1 1.5 Straight 10 1.5 3 Straight Straight Only
    The minimum area diameter(mm) F3 F7 F7 F4 F4 F5 F5 F7
    The critical thickness of the matrix(mm) 0.2 0.5 0.5 2 0.3 0.3 0.3 Unlimited

    Measuring Range
    F400:0~400μm N400:0~400μm
    F1:0~1250μm F1/90:0~1250μm
    N1:0~1250μm F10:0~10000μm
    CN02:10~200μm
    Accuracy
    F400、N400 Probe
    One point calibration: (2%+0.7)
    Two point calibration:±(1%+0.7)
    F1、F1/90、N1、CN02 Probe
    One point calibration:±(2%+1)
    Two point calibration:±(1%+1)
    F10 Probe
    One point calibration:±(2%+10)
    Two point calibration:±(1%+10)
    Calibration method
    One point calibration / two point calibration / Basic Calibration
    Resolution:0.1μm(0-99.9μm)
    1μm (over100μm)

    Probe Mode F400 F1 F1/90 F10 N400 N1 CN02
    Working Principle Magenetic Permeability Method Eddy Current Method
    Mesuring range 0~400 0~1250 0~10000 0~400 0~1250 10~200
    ( Copper covered with chomium  0~40)
    Resolution (mm) 0.1 0.1 10 0.1 0.1 1
    Tolera (mm) One point calibration(mm) ±(3%H+0.7) ±(3%H+1) ±(3%H+10) ±(3%H+0.7) ±(3%H+1.5) ±(3%H+1)
    Tne point calibration(m) ±(1%H+0.7) ±((1%H+1) ±(1%H+10) ±(1%H+0.7) ±(1%H+1.5) --------
    Measuring Condition The minimum radius of curvature(mm) 1 1.5 Straight 10 1.5 3 Straight Straight Only
    The minimum area diameter(mm) F3 F7 F7 F4 F4 F5 F5 F7
    The critical thickness of the matrix(mm) 0.2 0.5 0.5 2 0.3 0.3 0.3 Unlimited
     

    Base                     Coating

     

    Organic materials and other non metallic coating (such as: paint, paint, enamel,etc)

    Plastic and anodizing etc.)

     

    Cover thickness < 100mm Cover thickness > 100mm
    Such as magnetic metal iron, steel etc. Measuring Area > 30mm F400: 0~400mm

    F1  : 0~1250mm

    F400 :0~400mm

    F1  :0~1250mm

    F10  :0~10mm

    Measuring Area < 30mm F400: 0~400mm F1  : 0~1250mm

    F400: 0~400mm

    Such as copper, aluminum,  tin etc. Measuring Area > 10mm N400 :0~400mm

    N1   :0~1250mm

    N400 0~400mm

    N1 : 0~10mm

    Measuring Area < 10mm N400 :0~400mm N1 :  0~1250mm

    N400: 0~400mm

     

    Testing Probe Reference(2)

     

    Probe                     Coating

     

    Non magnetic metal layer (such as: chromium, zinc, aluminum,copper, tin, silver, etc.)
    Cover thickness < 100mm Cover thickness < 100mm
    Such as magnetic metal iron, steel etc. Measuring Area > 30mm F400: 0~400mm

    F1:   0~1250mm

    F400: 0~400mm

    F1:  0~1250mm

    F10:  0~10mm

    Measuring Area < 30mm F400: 0~400mm F400:0~400µm

    F1:  0~1250mm

    Such as copper, aluminum,  tin etc. Measuring Area > 10mm Only for copper plating N400: 0~40mm        --------
    Measuring Area < 10mm        --------        --------
    Plastic, non metal base Measuring Area > 7mm CN02: 10~200mm CN02: 10~200mm

    Testing Probe Reference(3)

    Mode Cpad T200 Cpad T210 Cpad T220
    Probe F N N、F

     

    Enquiry Form (we will get back to you ASAP)

    Name:
    *
    Email:
    *
    Message:

    Verification:
    3 + 4 = ?

    Maybe you like also